Test-Find-Test Data Reference Example

This example compares the results for test-find-test data.


Reference Case

International Standard IEC 61164 (Reliability Growth in Product Design and Test – Statistical Test and Estimation Methods), Example 4, pg. 32.


Data

Termination Time = 4000 hours
Failure Time Classification Mode
150 BD1
253 BD2
475 BD3
540 BD4
564 BD5
636 A
722 BD5
871 A
996 BD6
1003 BD7
1025 A
1120 BD8
1209 BD2
1255 BD9
1334 BD10
1647 BD9
1774 BD10
1927 BD11
2130 A
2214 A
2293 A
2448 A
2490 BD12
2508 A
2601 BD1
2635 BD8
2731 A
2747 BD6
2850 BD13
3040 BD9
3154 BD4
3171 A
3206 A
3245 DB12
3249 BD10
3420 BD5
3502 BD3
3646 BD10
3649 A
3663 BD2
3730 BD8
3794 BD14
3890 BD15
3949 A
3952 BD16


BD Mode EF
1 0.7
2 0.7
3 0.8
4 0.8
5 0.9
6 0.9
7 0.5
8 0.8
9 0.9
10 0.7
11 0.7
12 0.6
13 0.6
14 0.7
15 0.7
16 0.5


Result

BetaBD (UnB) = 0.7472, LambdaBD = 0.0326 Unseen BD Mode Failure Intensity = 0.0030/hr Goodness of fit for BD modes: CVM = 0.085, critical value = 0.171 with significance level = 0.1. Since CVM < critical value can fail to reject hypothesis that the model fits the data. DMTBF = 88.9 hours PMTBF = 135.1 hours


Results in Weibull++

Since test-find-test, the assumption is [math]\displaystyle{ \,\!\beta =1 }[/math]. Therefore:

[math]\displaystyle{ \begin{align} DMTBF=&\frac{T}{N}\\ =&\frac{4000}{45}\\ =&0.6153 \end{align}\,\! }[/math]



MIL-HDBK-189A 6.3.1.7.5 Example Results.png


MIL-HDBK-189A 6.3.1.7.5 Example Stats.png


MIL-HDBK-189A 6.3.1.7.5 Example Plot.png