The final equation in terms of the actual values of these two factors is: | The final equation in terms of the actual values of these two factors is: | ||
::<math>\begin{align} | ::<math>\begin{align} | ||
Yield= -1430.52285+7.80749 * time + 13.27053 * temp-0.05505 * time^2 - 0.04005 * temp^2 + 0.01 * time * temp | Yield= -1430.52285+7.80749 * time + 13.27053 * temp-0.05505 * time^2 - 0.04005 * temp^2 + 0.01 * time * temp | ||
\end{align}</math> | \end{align}</math> | ||
The maximum yield is achieved at 80.21 with time=87 minutes and temperature=176.5 F. | The maximum yield is achieved at 80.21 with time=87 minutes and temperature=176.5 F. | ||
{{Reference_Example_Heading4|DOE++}} | {{Reference_Example_Heading4|DOE++}} | ||
The software results match the book results: | The software results match the book results. The ANOVA table is: | ||
[[Image:composite_anova.png|center]] | [[Image:composite_anova.png|center]] |