With the Synthesis API, you can leverage the ALTA analysis engine to perform accelerated life testing data analysis on an external data source. In this tutorial, you will learn how to use the API to create and analyze a data set, and then use the result to estimate the B10 life.




==Tutorial: Accelerated Life Testing Data Analysis - Stress Profiles ==
==Tutorial: Accelerated Life Testing Data Analysis - Stress Profiles ==
The following example demonstrates how to define an ALTA data set and obtain analysis results from a single stress model. A discussion of the example follows.  
The following example demonstrates how to xxx. A discussion of the example follows.  


The following table shows the data set for this example.
The following table shows the data set for this example.
{|{{table}}
{|{{table}}
|Number in State||State||Time to F or S||Temperature
|+Stress Profile
|Start||End||Stress
|-
|0||200||125
|-
|200||300||175
|-
|300||350||200
|-
|350||375||250
|}
 
{|{{table}}
|+Data Set
|Number in State||State||Time to F or S
|-
|-
|1||F||245||353
|1||F||252
|-
|-
|5||S||250||353
|5||S||250
|-
|-
|1||F||110||373
|1||F||110
|-
|-
|1||F||180||373
|1||F||180
|-
|-
|1||F||200||373
|1||F||200
|-
|-
|3||S||250||373
|3||S||250
|-
|-
|1||F||50||393
|1||F||50
|-
|-
|1||F||70||393
|1||F||70
|-
|-
|1||F||88||393
|1||F||88
|-
|-
|1||F||112||393
|1||F||112
|-
|-
|1||F||140||393
|1||F||140
|-
|-
|1||F||160||393
|1||F||160
|}
|}



Revision as of 23:41, 11 May 2016

DRAFT

APIWiki.png


<< Back to Tutorials Main Page

xxxxx


Tutorial: Accelerated Life Testing Data Analysis - Stress Profiles

The following example demonstrates how to xxx. A discussion of the example follows.

The following table shows the data set for this example.

Stress Profile
Start End Stress
0 200 125
200 300 175
300 350 200
350 375 250
Data Set
Number in State State Time to F or S
1 F 252
5 S 250
1 F 110
1 F 180
1 F 200
3 S 250
1 F 50
1 F 70
1 F 88
1 F 112
1 F 140
1 F 160


VB.NET

Imports SynthesisAPI 

Module Module1
   Sub Main()

  'Declare a new ALTADataSet object.  
   Dim ADS As New ALTADataSet

  'Define a stress type with use stress level = 300.  
   ADS.AddStressDefinition("Stress1",,300)

  'Add failure times to the data set. 
   ADS.AddFailure(245, 1, 353)
   ADS.AddFailure(110, 1, 373)
   ADS.AddFailure(180, 1, 373)  
   ADS.AddFailure(200, 1, 373)
   ADS.AddFailure(50, 1, 393)
   ADS.AddFailure(70, 1, 393)
   ADS.AddFailure(88, 1, 393)
   ADS.AddFailure(112, 1, 393)
   ADS.AddFailure(140, 1, 393)
   ADS.AddFailure(160, 1, 393)
   
  'Add suspensions to the data set. 
   ADS.AddSuspension(250, 5, 353)   
   ADS.AddSuspension(250, 3, 373) 
 
  'Use the Arrhenius-Weibull model to analyze the data set. 
  'Keep all other analysis settings at default. 
   ADS.AnalysisSettings.ModelType = ALTASolverModel.Arrhenius
   ADS.AnalysisSettings.Distribution = ALTASolverDistribution.Weibull
 
  'Analyze the data set. 
   ADS.Calculate()

  'Calculate the B10 life and display the result. 
   Dim r As Double
   r = ADS.FittedModel.Time(.90)
   MsgBox("B10 Life: " & r)

   End Sub
End Module


Discussion

The ALTADataSet class represents an ALTA standard folio data sheet. The class contains all the methods and properties that allow you to define a data set and fit a life-stress relationship and distribution to the data.

 'Declare a new ALTADataSet object.  
  Dim ADS As New ALTADataSet

Use the AddStressDefinition method to define a stress type and the use stress level.

 'Define a stress type with use stress level = 300.  
  ADS.AddStressDefinition("Stress1",,300)

The data set can contain failures, suspensions or interval data. The following example shows how to use the AddFailure method to define failures and the AddSuspension method to define suspensions.

 'Add failure times to the data set. 
  ADS.AddFailure(245, 1, 353)
  ADS.AddFailure(110, 1, 373)
  ADS.AddFailure(180, 1, 373)  
  ADS.AddFailure(200, 1, 373)
  ADS.AddFailure(50, 1, 393)
  ADS.AddFailure(70, 1, 393)
  ADS.AddFailure(88, 1, 393)
  ADS.AddFailure(112, 1, 393)
  ADS.AddFailure(140, 1, 393)
  ADS.AddFailure(160, 1, 393)
   
 'Add suspensions to the data set. 
  ADS.AddSuspension(250, 5, 353)   
  ADS.AddSuspension(250, 3, 373) 

The AnalysisSetting property returns an ALTAAnalysisOptions object, which represents the analysis settings of the ALTADataSet object. In the following example, we use the ModelType and Distribution properties of the ALTAAnalysisOptions class to specify the life-stress relationship and distribution.

 'Use the Arrhenius-Weibull model to analyze the data set. 
 'Keep all other analysis settings at default. 
  ADS.AnalysisSettings.ModelType = ALTASolverModel.Arrhenius
  ADS.AnalysisSettings.Distribution = ALTASolverDistribution.Weibull

To analyze the data set, use the Calculate method. The method returns a message box that shows the estimated parameters of the model, based on the settings specified in the AnalysisSettings property.

 'Analyze the data set. 
  ADS.Calculate()

The FittedModel property gets a cModel object that represents the fitted model of the accelerated life testing data analysis. From the model, you can calculate useful metrics such as reliability, failure rate, mean time, etc. In this example, we calculate for the B10 life.

 'Calculate the B10 life and display the result. 
  Dim r As Double
  r = ADS.FittedModel.Time(.90)
  MsgBox("B10 Life: " & r)


Notes

For analyses that require a two-stress model, you will need to define two stress types, and then use the overloaded methods to add the data points. For example:

 ... 
 'Define two stress types.  
  ADS.AddStressDefinition("Temp",,328)
  ADS.AddStressDefinition("Voltage",,2)

 'Add failure times for Temp = 348 and Voltage = 3. 
  ADS.AddFailure(620, 1, 348, 3)
  ADS.AddFailure(632, 1, 348, 3)
 ... 

References