WeibullDataSet.CalculateBestFit

From ReliaWiki
Revision as of 21:39, 7 April 2016 by Kate Racaza (talk | contribs)
Jump to navigation Jump to search
APIWiki.png


Member of: SynthesisAPI.WeibullDataSet


Performs goodness of fit tests to find the distribution that best fits the data set (similar to the Distribution Wizard feature in Weibull++). Returns a message box that shows the estimated parameters of the distribution that best fits the data and creates a retrievable cModel object that represents the fitted model from the life data analysis.

Use the BestFitSettings property of the class to specify the criteria for evaluating the fit.

Syntax

.CalculateBestFit

Example

VBA

 'Declare a new WeibullDataSet object.  
  Dim WDS As New WeibullDataSet

 'Add failure times to the data set. 
  Call WDS.AddFailure(100, 1)
  Call WDS.AddFailure(120, 1)
  Call WDS.AddFailure(130, 1)  
 
 'Consider the normal, lognormal and 2-parameter Weibull distributions in the evaluation. 
  WDS.BestFitSettings.AllowExponential1 = False
  WDS.BestFitSettings.AllowExponential2 = False
  WDS.BestFitSettings.AllowNormal = True
  WDS.BestFitSettings.AllowLognormal = True
  WDS.BestFitSettings.AllowWeibull2 = True
  WDS.BestFitSettings.AllowWeibull3 = False
  WDS.BestFitSettings.AllowGamma = False
  WDS.BestFitSettings.AllowGenGamma = False
  WDS.BestFitSettings.AllowLogistic = False
  WDS.BestFitSettings.AllowLoglogistic = False
  WDS.BestFitSettings.AllowGumbel = False
 
 'Perform the goodness of fit tests. 
  Call WDS.CalculateBestFit()
 
 'Retrieve the fitted life distribution model. 
  Dim model As cModel
  Set model = WDS.FittedModel

 'Using the model, calculate the reliability at 100 hrs and display the result. 
  Dim r As Double
  r = model.reliability(100)
  MsgBox("Reliability at 100 hrs: " & r)
VB.NET

 'Declare a new WeibullDataSet object.  
  Dim WDS As New WeibullDataSet

 'Add failure times to the data set. 
  WDS.AddFailure(100, 1)
  WDS.AddFailure(120, 1)
  WDS.AddFailure(130, 1)  
 
 'Consider the normal, lognormal and 2-parameter Weibull distributions in the evaluation. 
  WDS.BestFitSettings.AllowExponential1 = False
  WDS.BestFitSettings.AllowExponential2 = False
  WDS.BestFitSettings.AllowNormal = True
  WDS.BestFitSettings.AllowLognormal = True
  WDS.BestFitSettings.AllowWeibull2 = True
  WDS.BestFitSettings.AllowWeibull3 = False
  WDS.BestFitSettings.AllowGamma = False
  WDS.BestFitSettings.AllowGenGamma = False
  WDS.BestFitSettings.AllowLogistic = False
  WDS.BestFitSettings.AllowLoglogistic = False
  WDS.BestFitSettings.AllowGumbel = False
 
 'Perform the goodness of fit tests. 
  WDS.CalculateBestFit()
 
 'Retrieve the fitted life distribution model. 
  Dim model As cModel
  model = WDS.FittedModel

 'Using the model, calculate the reliability at 100 hrs and display the result. 
  Dim r As Double
  r = model.reliability(100)
  MsgBox("Reliability at 100 hrs: " & r)