Multiple Systems (Known Operating Times) Data Reference Example
From ReliaWiki
Revision as of 20:28, 9 June 2014 by Beth Ann Paape (talk | contribs)
RGA_Reference_Examples_Banner.png
RGA_Reference_Examples |
This example compares the results for multiple systems (known operating times) data.
Reference Case
MIL-HDBK-189A, Section 6.3.1.6.4, pg. 156, 2009.
Data
Termination Time = 300 hours
| ||
---|---|---|
Prototype #1 | Prototype #2 | Cumulative Time |
*2.6 | 0 | 2.6 |
*16.5 | 0 | 16.5 |
*16.5 | 0 | 16.5 |
*17 | 0 | 17 |
20.5 | *0.9 | 21.4 |
25.3 | *3.8 | 29.1 |
28.7 | *4.6 | 33.3 |
*41.8 | 14.7 | 56.5 |
*45.5 | 17.6 | 63.1 |
48.6 | *22 | 70.6 |
49.6 | *23.4 | 73 |
*51.4 | 26.3 | 77.7 |
*58.2 | 35.7 | 93.9 |
59 | *36.5 | 95.5 |
60.5 | *37.6 | 98.1 |
*61.9 | 39.1 | 101.1 |
*76.6 | 55.4 | 132 |
81.1 | *61.1 | 142.2 |
*84.1 | 63.6 | 147.7 |
*84.7 | 64.3 | 149 |
*94.6 | 72.6 | 167.2 |
104.8 | *85.9 | 190.7 |
105.9 | *87.1 | 193 |
*108.8 | 89.9 | 198.7 |
132.4 | *119.5 | 251.9 |
132.4 | *150.1 | 282.5 |
132.4 | *153.7 | 286.1 |
Result
Beta = 0.716, Lambda – 0.454
DMTBF = 15.5 hours
Using significance level = 0.05. CVM = 0.091. Critical value = 0.218. Since CVM < critical value can fail to reject hypothesis that model fits the data.
Results in RGA