Test-Fix-Test Data (Failure Terminated) Reference Example
From ReliaWiki
Revision as of 20:19, 9 June 2014 by Kate Racaza (talk | contribs)
RGA_Reference_Examples_Banner.png
RGA_Reference_Examples |
This example compares the results for test-fix-test data (failure terminated).
Reference Case
International Standard IEC 61164 (Reliability Growth in Product Design and Test – Statistical Test and Estimation Methods), Example 1 – Case 2, pg. 30.
Data
Termination Time = 975 hours |
---|
2 |
4 |
10 |
15 |
18 |
19 |
20 |
25 |
39 |
41 |
43 |
45 |
47 |
66 |
88 |
97 |
104 |
105 |
120 |
196 |
217 |
219 |
257 |
260 |
281 |
283 |
289 |
307 |
329 |
357 |
372 |
374 |
393 |
403 |
466 |
521 |
556 |
571 |
621 |
628 |
642 |
684 |
732 |
735 |
754 |
792 |
803 |
805 |
832 |
836 |
873 |
975 |
Result
Beta (UnB) = 0.5594, Lambda = 1.1067
CL = 0.9 (two-sided confidence bounds on DMTBF
DMTBFUpper = 46.7 hours
DMTBF = 33.5 hours
DMTBFLower = 24.3 hours
CVM = 0.041, critical value = 0.173. Since CVM < critical value can fail to reject hypothesis that the model fits the data.
Results in RGA
Confidence bounds in QCP are calculated using Crow Bounds methodology.