Test-Fix-Test Data Reference Example
Jump to navigation
Jump to search
New format available! This reference is now available in a new format that offers faster page load, improved display for calculations and images and more targeted search.
As of January 2024, this Reliawiki page will not continue to be updated. Please update all links and bookmarks to the latest references at RGA examples and RGA reference examples.
This example compares the results for test-fix-test data (time terminated).
Reference Case
Crow, L.H., Confidence Interval Procedures for the Weibull Process with Applications to Reliability Growth, U.S. Army Material Systems Analysis Activity, 1981.
Data
Termination Time = 500 hours |
---|
0.2 |
4.2 |
4.5 |
5 |
5.4 |
6.1 |
7.9 |
14.8 |
19.2 |
48.6 |
85.8 |
108.9 |
127.2 |
129.8 |
150.1 |
159.7 |
227.4 |
244.7 |
262.7 |
315.3 |
329.6 |
404.3 |
486.2 |
Result
Beta = 0.413, Lambda = 1.769
DMTBF = 52.7
Confidence Bounds on DMTBF (CL = 80%) = (35.6, 82.9)
Results in Weibull++
- [math]\displaystyle{ \begin{align} \hat{\beta }=&\frac{N}{{N\ln T^{*}}-\sum_{i=1}^{N}T_{i}}\\ \\ =&\frac{23}{{23\cdot \ln \left ( 500 \right )}-87.2106}\\ \\ =&0.4127 \end{align}\,\! }[/math]