Returns the failure rate at the specified time.

Syntax

  • FailureRate( Time As Double , Optional CurrentAge As Double = 0 , Optional DutyCycle As Double = 1 ) As Double

Parameters

Time: The time at which the failure rate is calculated.
CurrentAge: The current age.
DutyCycle: The duty cycle.

Usage Example

 'Declare the cModel class using an in-line parameter list. 
 Dim newModel As New cModel(ModelTypeEnum.Weibull2, 
   ModelCategoryEnum.Reliability, "NewModel1", 1, 100)
 
 'Calculate the failure rate at time = 100. 
 Dim ResultValue as Double
 ResultValue = newModel.FailureRate(100)