WeibullDataSet.AddFailureInterval

From ReliaWiki
Jump to navigation Jump to search


Adds interval censored failures to the data set, using the specified start/end times and number of failures that occurred within the interval.

Syntax

  • AddFailureInterval( StartValueAs Double, EndValueAs Double, NumberInGroupAs Integer)

Parameters

StartValue: The starting value of the failure interval.
EndValue: The ending value of the failure interval.
NumberInGroup: The number of failures that occurred during the interval.

Usage Example

 'Declare a new WeibullDataSet object. See WeibullDataSet. 
 Dim WDS as New WeibullDataSet
 
 'Add three interval censored data points. 
 WDS.AddFailureInterval(1, 5, 1)
 WDS.AddFailureInterval(6, 10, 1)
 WDS.AddFailureInterval(11, 15, 1)