cModel.FailureRate

From ReliaWiki
Revision as of 15:25, 7 March 2014 by Chris Kahn (talk | contribs)
Jump to navigation Jump to search


Returns the failure rate at the specified time.

Syntax

  • FailureRate( Time As Double , Optional CurrentAge As Double = 0 , Optional DutyCycle As Double = 1 ) As Double

Parameters

Time: The time at which the failure rate is calculated.
CurrentAge: The current age.
DutyCycle: The duty cycle.

Usage Example

Declare the cModel class using an in-line parameter list.

       Dim newModel As New cModel(ModelTypeEnum.Weibull2, ModelCategoryEnum.Reliability, "NewModel1", 1, 100)

Calculate the Failure Rate at time 100 for the model described in newModel.

       Dim ResultValue as Double
       ResultValue = newModel.FailureRate(100)