Data is from an example on page 530in the book ''Experiments, planning, analysis, and parameter design optimization'' by C.F. Jeff Wu, Michael Hamad, John Wiley & Sons, Inc. 2000.
Data is from an example on page 530 and page 544 in the book ''Experiments, planning, analysis, and parameter design optimization'' by C.F. Jeff Wu, Michael Hamad, John Wiley & Sons, Inc. 2000.


{{Reference_Example_Heading2}}
{{Reference_Example_Heading2}}
Line 18: Line 18:
!style="background:#f0f0f0;"|E
!style="background:#f0f0f0;"|E
|-
|-
| 1||-||-||-||-||-||(14, 16)||(20, \inf)
| 1||-||-||-||-||-||(14, 16)||(20, <math>\infty\,\!</math>)
|-
|-
| 2||-||-||+||+||+||(18,20)||(20, \inf)
| 2||-||-||+||+||+||(18,20)||(20, <math>\infty\,\!</math>)
|-
|-
| 3||-||+||-||-||+||(8, 10)||(10, 12)
| 3||-||+||-||-||+||(8, 10)||(10, 12)
|-
|-
| 4||-||+||+||+||-||(18, 20)||(20, \inf)
| 4||-||+||+||+||-||(18, 20)||(20, <math>\infty\,\!</math>)
|-
|-
| 5||+||-||+||-||+||(20, \inf)||(20, \inf)
| 5||+||-||+||-||+||(20, <math>\infty\,\!</math>)||(20, <math>\infty\,\!</math>)
|-
|-
| 6||+||-||+||-||+||(12, 14)||(20, \inf)
| 6||+||-||+||-||+||(12, 14)||(20, <math>\infty\,\!</math>)
|-
|-
| 7||+||+||-||+||+||((16, 18)||(20, \inf)
| 7||+||+||-||+||+||(16, 18)||(20, <math>\infty\,\!</math>)
|-
|-
| 8||+||+||+||-||-||(12, 14)||(14, 16)
| 8||+||+||+||-||-||(12, 14)||(14, 16)

Revision as of 18:24, 14 July 2015

DOE Reference Examples Banner.png


New format available! This reference is now available in a new format that offers faster page load, improved display for calculations and images and more targeted search.

As of January 2024, this Reliawiki page will not continue to be updated. Please update all links and bookmarks to the latest references at DOE examples and DOE reference examples.




R-DOE Design

This example validates the calculation of the reliability DOE design.

Reference Case

Data is from an example on page 530 and page 544 in the book Experiments, planning, analysis, and parameter design optimization by C.F. Jeff Wu, Michael Hamad, John Wiley & Sons, Inc. 2000.

Data Data

Run Factor Failure Time
A B C D E
1 - - - - - (14, 16) (20, [math]\displaystyle{ \infty\,\! }[/math])
2 - - + + + (18,20) (20, [math]\displaystyle{ \infty\,\! }[/math])
3 - + - - + (8, 10) (10, 12)
4 - + + + - (18, 20) (20, [math]\displaystyle{ \infty\,\! }[/math])
5 + - + - + (20, [math]\displaystyle{ \infty\,\! }[/math]) (20, [math]\displaystyle{ \infty\,\! }[/math])
6 + - + - + (12, 14) (20, [math]\displaystyle{ \infty\,\! }[/math])
7 + + - + + (16, 18) (20, [math]\displaystyle{ \infty\,\! }[/math])
8 + + + - - (12, 14) (14, 16)


Result Your text here.

Results in DOE++

Your text here.