A valid Part must meet the following requirements:
 
* The PartName or PartNumber element must be present
 
* The PartName or PartNumber element must contain a value
:{{Template:XFRACAS.Blue|<!—}}{{APIComment|The PartName or PartNumber element must be present and contain a value. }}
If the combination of PartName, PartNumber and PartVersion match an existing part, then it will be used. (Either PartName or PartNumber is required.)
:{{Template:XFRACAS.Blue|<!—}}{{APIComment|If the combination of PartName, PartNumber and PartVersion match an existing part, then the existing part will be updated.}}
:{{Template:XFRACAS.Blue|<Part>}}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|PartID must be an integer. If left without a value, a new PartID will be assigned.}}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|If PartID value matches an existing PartID, the part will be updated.}}
::<font color=Blue><PartID></font><font color=black>123</font><font color=Blue></PartID></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|PartName must be a String. 255 characters maximum }}
::'''<font color=Blue><PartName></font><font color=black>Synthesis Platform</font><font color=Blue></PartName></font>'''
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|PartNumber must be a String. 75 characters maximum}}
::'''<font color=Blue><PartNumber></font><font color=black>SYN</font><font color=Blue></PartNumber></font>'''
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|Sets whether a part is retired. “Yes” means it’s retired. “No” means it’s not retired. Default setting is “No.”}}
::<font color=Blue><Retired></font><font color=black>No</font><font color=Blue></Retired></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|PartVersion must be a String. 50 characters maximum }}
::<font color=Blue><PartVersion></font><font color=black>9</font><font color=Blue></PartVersion></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|CreatedDate must be a [[Valid Date]]. Valid Date can be exemplified under Common Elements.}}
::<font color=Blue><CreatedDate/></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|UseExisting is required for a (Template) System. It must be “Yes” or “No.”}}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|If “Yes” an identical part that exists in the same entity will be used. If “No” a new part will always be inserted.}}
::<font color=Blue><UseExisting/></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|Subpart is required to update a System. A Valid Part is required within a Subpart. See (Template) System.}}
::<font color=Blue><Subpart/></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|Entity must be a valid entity. [[Valid Entity]] can be exemplified under Common Elements.}}
::<font color=Blue><Entity/></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|HID must be an integer. If present it must match an existing HID.}}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|When modifying System Part data, HID must not be used within Subparts in order for the System to update.}}
::<font color=Blue><HID></font><font color=black>2</font><font color=Blue></HID></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|SerialHID must be an integer. It is required for serialized incidents.}}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|For serialized incidents, the SerialHID and/or SerialNumber must match an existing top level serial system.}}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|When modifying System data, SerialHID must not be used within Subparts in order for the System to update.}}
::<font color=Blue><SerialHID></font><font color=black>29</font><font color=Blue></SerialHID></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|SerialNumber must be a string. It is required for serialized incidents. }}
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|For serialized incidents, the SerialHID and/or SerialNumber must match an existing top level serial system.}}
::<font color=Blue><SerialNumber></font><font color=black>989</font><font color=Blue></SerialNumber></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|TimeMetric1 is a reliability time metric and does not inherently contain units. It is a floating (decimal) number.}}
::<font color=Blue><TimeMetric1></font><font color=black>10</font><font color=Blue></TimeMetric1></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|TimeMetric2 is a reliability time metric and does not inherently contain units. It is a floating (decimal) number.}}
::<font color=Blue><TimeMetric2></font><font color=black>12</font><font color=Blue></TimeMetric2></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|TimeMetric3 is a reliability time metric and does not inherently contain units. It is a floating (decimal) number.}}
::<font color=Blue><TimeMetric3></font><font color=black>2.2</font><font color=Blue></TimeMetric3></font>
::{{Template:XFRACAS.Blue|<!—}}{{APIComment|Details are documented within Details.}}
::<font color=Blue><Details/></font>
:{{Template:XFRACAS.Blue|</Part>}}

Revision as of 22:58, 12 February 2015


<!— The PartName or PartNumber element must be present and contain a value.
<!— If the combination of PartName, PartNumber and PartVersion match an existing part, then the existing part will be updated.
<Part>
<!— PartID must be an integer. If left without a value, a new PartID will be assigned.
<!— If PartID value matches an existing PartID, the part will be updated.
<PartID>123</PartID>
<!— PartName must be a String. 255 characters maximum
<PartName>Synthesis Platform</PartName>
<!— PartNumber must be a String. 75 characters maximum
<PartNumber>SYN</PartNumber>
<!— Sets whether a part is retired. “Yes” means it’s retired. “No” means it’s not retired. Default setting is “No.”
<Retired>No</Retired>
<!— PartVersion must be a String. 50 characters maximum
<PartVersion>9</PartVersion>
<!— CreatedDate must be a Valid Date. Valid Date can be exemplified under Common Elements.
<CreatedDate/>
<!— UseExisting is required for a (Template) System. It must be “Yes” or “No.”
<!— If “Yes” an identical part that exists in the same entity will be used. If “No” a new part will always be inserted.
<UseExisting/>
<!— Subpart is required to update a System. A Valid Part is required within a Subpart. See (Template) System.
<Subpart/>
<!— Entity must be a valid entity. Valid Entity can be exemplified under Common Elements.
<Entity/>
<!— HID must be an integer. If present it must match an existing HID.
<!— When modifying System Part data, HID must not be used within Subparts in order for the System to update.
<HID>2</HID>
<!— SerialHID must be an integer. It is required for serialized incidents.
<!— For serialized incidents, the SerialHID and/or SerialNumber must match an existing top level serial system.
<!— When modifying System data, SerialHID must not be used within Subparts in order for the System to update.
<SerialHID>29</SerialHID>
<!— SerialNumber must be a string. It is required for serialized incidents.
<!— For serialized incidents, the SerialHID and/or SerialNumber must match an existing top level serial system.
<SerialNumber>989</SerialNumber>
<!— TimeMetric1 is a reliability time metric and does not inherently contain units. It is a floating (decimal) number.
<TimeMetric1>10</TimeMetric1>
<!— TimeMetric2 is a reliability time metric and does not inherently contain units. It is a floating (decimal) number.
<TimeMetric2>12</TimeMetric2>
<!— TimeMetric3 is a reliability time metric and does not inherently contain units. It is a floating (decimal) number.
<TimeMetric3>2.2</TimeMetric3>
<!— Details are documented within Details.
<Details/>
</Part>