WeibullDataSet.AddFailureInterval: Difference between revisions
Jump to navigation
Jump to search
Chris Kahn (talk | contribs) No edit summary |
Chris Kahn (talk | contribs) No edit summary |
||
Line 4: | Line 4: | ||
== Syntax == | == Syntax == | ||
{{APIComment|'Declaration}} | {{APIComment|'Declaration}} | ||
AddFailureInterval( StartValue {{APIPrefix|As Double}} , EndValue {{APIPrefix|As Double}} , NumberInGroup {{APIPrefix|As Integer}} ) | AddFailureInterval({{APIPrefix|ByVal}}StartValue{{APIPrefix|As Double}},{{APIPrefix|ByVal}}EndValue{{APIPrefix|As Double}},{{APIPrefix|ByVal}}NumberInGroup {{APIPrefix|As Integer}}) | ||
Parameters | Parameters |
Revision as of 23:13, 19 February 2014
Adds interval censored failures to the data set, using the specified start/end times and number of failures that occurred within the interval.
Syntax
'Declaration AddFailureInterval(ByValStartValueAs Double,ByValEndValueAs Double,ByValNumberInGroup As Integer)
Parameters
- StartValue: The starting value of this failure interval.
- EndValue: The ending value of this failure interval.
- NumberInGroup: The number of units that failed during this interval.
Usage Example
Declare the WeibullDataSet. See New WeibullDataSet for additional details.
Dim WDS as New WeibullDataSet
Add values to the raw data.
WDS.AddFailureInterval(1, 5, 1) WDS.AddFailureInterval(6, 10, 1) WDS.AddFailureInterval(11, 15, 1)