Line 4: | Line 4: | ||
== Properties == | == Properties == | ||
* | *{{Template:WeibullGeneralOptions.WarnNegLocation|WarnNegLocation}} {{APIComment|{{Template:WeibullGeneralOptions.WarnNegLocation.Cmt}}}} | ||
* | *{{Template:WeibullGeneralOptions.DiscardNegLocation|DiscardNegLocation}} {{APIComment|{{Template:WeibullGeneralOptions.DiscardNegLocation.Cmt}}}} | ||
* | *{{Template:WeibullGeneralOptions.ResetExpLocation|ResetExpLocation}} {{APIComment|{{Template:WeibullGeneralOptions.ResetExpLocation.Cmt}}}} | ||
* | *{{Template:WeibullGeneralOptions.Use3PTrueMLE|Use3PTrueMLE}} {{APIComment|{{Template:WeibullGeneralOptions.Use3TrueMLE.Cmt}}}} | ||
* | *{{Template:WeibullGeneralOptions.UseExtendedGGamma|UseExtendedGGamma}} {{APIComment|{{Template:WeibullGeneralOptions.UseExtendedGGamma.Cmt}}}} | ||
* | *{{Template:[WeibullGeneralOptions.AllowBiasingNormal|AllowBiasingNormal}} {{APIComment|{{Template:WeibullGeneralOptions.AllowBiasingNormal.Cmt}}}} | ||
* | *{{Template:WeibullGeneralOptions.UsePlottedYPoints|UsePlottedYPoints}} {{APIComment|{{Template:WeibullGeneralOptions.UsePlottedYPoints.Cmt}}}} | ||
== Formatted Usage Example == | == Formatted Usage Example == |
Revision as of 20:33, 6 February 2014
This class describes various settings for WeibullDataSet's GeneralSettings.
Properties
- WarnNegLocation As Boolean Sets whether a warning will be generated when the location parameter contains a negative value.
- DiscardNegLocationAs Boolean Sets whether to discard the location parameter when it contains a negative value.
- ResetExpLocation As Boolean Sets whether to reset the value of the location parameter equal to the first failure time, T1, if the parameter is greater than T1. (Exponential distribution only.)
- Template:WeibullGeneralOptions.Use3PTrueMLE Sets whether to use a true 3-parameter MLE solution for 3-parameter Weibull.
- UseExtendedGGamma As Boolean Sets whether to allow the lambda parameter of the generalized gamma distribution to take negative values.
- {{Template:[WeibullGeneralOptions.AllowBiasingNormal|AllowBiasingNormal}} Sets whether to correct the MLE standard deviation (sigma) value for biasedness (complete data only).
- UsePlottedYPoints As Boolean Sets whether to use the plotted points (using median ranks or Kaplan-Meier) to calculate the difference between observed and model estimated probability for the Kolmogorov-Smirnov test.
Formatted Usage Example
Declare the WeibullDataSet. See New WeibullDataSet for additional details.
Dim WDS as New WeibullDataSet
Set various settings.
WDS.GeneralSettings.AllowBiasingNormal = False WDS.GeneralSettings.DiscardNegLocation = False WDS.GeneralSettings.ResetExpLocation = True WDS.GeneralSettings.Use3PTrueMLE = False WDS.GeneralSettings.UseExtendedGGamma = False WDS.GeneralSettings.UsePlottedYPoints = False WDS.GeneralSettings.WarnNegLocation = False