Objective This example uses time-to-failure data from a life test done on incandescent light bulbs.
 
Consider the following times to failure
 
 
 
 
 
{| border="1" cellspacing="1" cellpadding="4" width="300" align="center"
|+ Observed times-to-failure for ten bulbs in hours.
|-
! valign="middle" scope="col" align="center" | Order Number
! valign="middle" scope="col" align="center" | Hours-to-failure
|-
| valign="middle" align="center" | 1
| valign="middle" align="center" | 361
|-
| valign="middle" align="center" | 2
| valign="middle" align="center" | 680
|-
| valign="middle" align="center" | 3
| valign="middle" align="center" |  721
|-
| valign="middle" align="center" | 4
| valign="middle" align="center" | 905
|-
| valign="middle" align="center" | 5
| valign="middle" align="center" | 1010
|-
| valign="middle" align="center" | 6
| valign="middle" align="center" |  1090
|-
| valign="middle" align="center" | 7
| valign="middle" align="center" | 1157
|-
| valign="middle" align="center" | 8
| valign="middle" align="center" | 1330
|-
| valign="middle" align="center" | 9
| valign="middle" align="center" | 1400
|-
| valign="middle" align="center" | 10
| valign="middle" align="center" | 1695
|}
 
 
 
[[Category:Weibull_Examples]]

Revision as of 03:14, 25 June 2011

Objective This example uses time-to-failure data from a life test done on incandescent light bulbs.

Consider the following times to failure

 


Observed times-to-failure for ten bulbs in hours.
Order Number Hours-to-failure
1 361
2 680
3  721
4 905
5 1010
6  1090
7 1157
8 1330
9 1400
10 1695