This example | This example validates the results for multiple systems (known operating times) data in RGA. | ||
Line 6: | Line 6: | ||
MIL-HDBK-189A, Section 6.3.1.6.4, pg. 156, 2009. | MIL-HDBK-189A, Section 6.3.1.6.4, pg. 156, 2009. | ||
For this example, the following will be calculated: | |||
*Parameters of the Crow-AMSAA (NHPP) model | |||
*Demonstrated MTBF (DMTBF) | |||
*Cramér-von Mises (CVM) goodness-of-fit | |||
Line 89: | Line 94: | ||
{{Reference_Example_Heading4|RGA}} | {{Reference_Example_Heading4|RGA}} | ||
In RGA, the Crow-AMSAA (NHPP) model with the maximum likelihood estimation (MLE) method was used to calculate the results. | |||
*The model parameters are: | |||
[[image:MIL-HDBK-189A 6.3.1.6.4 Example_Results.png|center]] | [[image:MIL-HDBK-189A 6.3.1.6.4 Example_Results.png|center]] | ||
*The Cramér-von Mises (CVM) goodness-of-fit test results: | |||
[[image:MIL-HDBK-189A 6.3.1.6.4 Example_Stat Tests.png|center]] | [[image:MIL-HDBK-189A 6.3.1.6.4 Example_Stat Tests.png|center]] |