<onlyinclude>A parameterized constructor for the [[CModel Class|cModel]] class. (.NET only)</onlyinclude> | |||
== Syntax == | == Syntax == | ||
'''cModel'''(''ModelType'', ''ModelCategory'', ''ModelName'', {{APIPrefix|ParamArray}} ''ModelParams()'') | |||
===Parameters=== | |||
''ModelType'' | |||
:Required. The type of model (e.g., 2-parameter Weibull). Can be any of the model types listed in the table below. The model types are part of the [[ModelTypeEnum Enumeration|ModelTypeEnum]]. | |||
''ModelCategory'' | |||
:Required. The model category (e.g., reliability model). Can be any [[ModelCategoryEnum Enumeration|ModelCategoryEnum]] constant. | |||
''ModelName'' | |||
:Required. String. The model name. | |||
''ModelParams()'' | |||
:Required. Double. An array of the model's parameters. The table below shows the order of the parameters in the array, for each type of model. | |||
{|border="1" cellpadding="5" cellspacing="0" style="border-collapse: collapse; text-align: left; cellborder" | |||
|- style="background:#F2F2F2;" | |||
!<span style="color:#585858;">Model Type</span> | |||
!<span style="color:#585858;">Enum Value</span> | |||
!<span style="color:#585858;">Order of Parameters</span> | |||
|- | |||
|Weibull1<br>Weibull2<br>Weibull3||100<br>101<br>102||style="width: 550px;"|Beta, Eta, Gamma | |||
|- | |||
|style="width: 130px;"|MixedWeibull2<br>MixedWeibull3<br>MixedWeibull4||style="width: 90px;"|103<br>104<br>105||Subpop1-Beta, Subpop1-Eta, Subpop1-Portion, Subpop2-Beta, Subpop2-Eta, Subpop2-Portion, Subpop3-Beta, Subpop3-Eta, Subpop3-Portion, Subpop4-Beta, Subpop4-Eta, Subpop4-Portion | |||
|- | |||
|Exponential1<Br>Exponential2||106<br>107||Lambda, Gamma | |||
|- | |||
|Normal||108||Mean, Std | |||
|- | |||
|Lognormal||109||LogMean, LogStd | |||
|- | |||
|GenGamma||110||Mu, K | |||
|- | |||
|Gamma||111||Mu, K | |||
|- | |||
|Logistic||112||Mu, Sigma | |||
|- | |||
|LogLogistic||113||Mu, Sigma | |||
|- | |||
|Gumbel||114||Mu, Sigma | |||
|- | |||
|FixedUnreliability||0||rowspan="3"|If creating a constant model, enter a value for Parameter 1, the set Parameter 2 to zero (0) or nothing. <br>If creating a dynamic model, enter the numeric ID of the variable resource for Parameter 2, then set Parameter 1 to zero (0) or nothing. If the variable does not exist, it creates a dynamic model with no predefined variable. | |||
|- | |||
|FixedDuration||1 | |||
|- | |||
|FixedCost||2 | |||
|} | |||
== Example == | |||
'''VB.NET''' | |||
{{APIComment|'The following code creates a 2-parameter Weibull reliability model,}} | |||
{{APIComment|'with beta 1 and eta 100. The model name is "MyNewModel."}} | |||
{{APIPrefix|Dim}} ModelParams(1) {{APIPrefix|As Double}} | |||
ModelParams(0) = 1 | |||
ModelParams(1) = 100 | |||
{{APIPrefix|Dim}} newModel {{APIPrefix|As New}} cModel(ModelTypeEnum.Weibull2,ModelCategoryEnum.Reliability, {{APIString|"MyNewModel"}}, ModelParams) | |||
{{APIComment|'Alternatively, you can create a new model using an in-line parameter list.}} | |||
{{APIPrefix|Dim}} newModel {{APIPrefix|As New}} cModel(ModelTypeEnum.Weibull2, ModelCategoryEnum.Reliability, {{APIString|"MyNewModel"}}, 1, 100) |
Latest revision as of 15:14, 3 August 2017
Member of: SynthesisAPI.cModel
A parameterized constructor for the cModel class. (.NET only)
Syntax
cModel(ModelType, ModelCategory, ModelName, ParamArray ModelParams())
Parameters
ModelType
- Required. The type of model (e.g., 2-parameter Weibull). Can be any of the model types listed in the table below. The model types are part of the ModelTypeEnum.
ModelCategory
- Required. The model category (e.g., reliability model). Can be any ModelCategoryEnum constant.
ModelName
- Required. String. The model name.
ModelParams()
- Required. Double. An array of the model's parameters. The table below shows the order of the parameters in the array, for each type of model.
Model Type | Enum Value | Order of Parameters |
---|---|---|
Weibull1 Weibull2 Weibull3 |
100 101 102 |
Beta, Eta, Gamma |
MixedWeibull2 MixedWeibull3 MixedWeibull4 |
103 104 105 |
Subpop1-Beta, Subpop1-Eta, Subpop1-Portion, Subpop2-Beta, Subpop2-Eta, Subpop2-Portion, Subpop3-Beta, Subpop3-Eta, Subpop3-Portion, Subpop4-Beta, Subpop4-Eta, Subpop4-Portion |
Exponential1 Exponential2 |
106 107 |
Lambda, Gamma |
Normal | 108 | Mean, Std |
Lognormal | 109 | LogMean, LogStd |
GenGamma | 110 | Mu, K |
Gamma | 111 | Mu, K |
Logistic | 112 | Mu, Sigma |
LogLogistic | 113 | Mu, Sigma |
Gumbel | 114 | Mu, Sigma |
FixedUnreliability | 0 | If creating a constant model, enter a value for Parameter 1, the set Parameter 2 to zero (0) or nothing. If creating a dynamic model, enter the numeric ID of the variable resource for Parameter 2, then set Parameter 1 to zero (0) or nothing. If the variable does not exist, it creates a dynamic model with no predefined variable. |
FixedDuration | 1 | |
FixedCost | 2 |
Example
VB.NET 'The following code creates a 2-parameter Weibull reliability model, 'with beta 1 and eta 100. The model name is "MyNewModel." Dim ModelParams(1) As Double ModelParams(0) = 1 ModelParams(1) = 100 Dim newModel As New cModel(ModelTypeEnum.Weibull2,ModelCategoryEnum.Reliability, "MyNewModel", ModelParams) 'Alternatively, you can create a new model using an in-line parameter list. Dim newModel As New cModel(ModelTypeEnum.Weibull2, ModelCategoryEnum.Reliability, "MyNewModel", 1, 100)