WeibullDataSet.AddFailureInterval: Difference between revisions

From ReliaWiki
Jump to navigation Jump to search
No edit summary
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Template:APIClass|WeibullDataSet Class|WeibullDataSet}}
{{Template:API}}{{Template:APIBreadcrumb|.[[WeibullDataSet Class|WeibullDataSet]]}}
{{Template:WeibullDataSet.AddFailureInterval.Cmt}}


== Syntax ==
*AddFailureInterval( StartValue{{APIPrefix|As Double}}, EndValue{{APIPrefix|As Double}}, NumberInGroup{{APIPrefix|As Integer}})
Parameters
:''StartValue'': The starting value of this failure interval.
:''EndValue'': The ending value of this failure interval.
:''NumberInGroup'': The number of units that failed during this interval.


== Usage Example ==
<onlyinclude>Adds interval censored failures to the data set.</onlyinclude>


{{APIComment|Declare the WeibullDataSet. See [[New WeibullDataSet]] for additional details.}}
== Syntax  ==
        Dim WDS as New WeibullDataSet
'''.AddFailureInterval'''(''StartValue'', ''EndValue'', ''NumberInGroup'')


{{APIComment|Add values to the raw data.}}
===Parameters===
        WDS.AddFailureInterval(1, 5, 1)
''StartValue''
        WDS.AddFailureInterval(6, 10, 1)
:Required. Double. The starting value of the failure interval.
        WDS.AddFailureInterval(11, 15, 1)
 
''EndValue''
:Required. Double. The ending value of the failure interval.
 
''NumberInGroup''
:Required. Double. The number of failures that occurred during the interval.
 
== Example ==
'''VBA'''
{{APIComment|'Declare a new WeibullDataSet object.}}
  {{APIPrefix|Dim}} WDS {{APIPrefix|As New}} WeibullDataSet
 
{{APIComment|'Add three interval censored data points.}}
  {{APIPrefix|Call}} WDS.AddFailureInterval(1, 5, 1)
  {{APIPrefix|Call}} WDS.AddFailureInterval(6, 10, 1)
  {{APIPrefix|Call}} WDS.AddFailureInterval(11, 15, 1)
 
'''VB.NET'''
{{APIComment|'Declare a new WeibullDataSet object.}}
  {{APIPrefix|Dim}} WDS {{APIPrefix|As New}} WeibullDataSet
 
{{APIComment|'Add three interval censored data points.}}  
  WDS.AddFailureInterval(1, 5, 1)
  WDS.AddFailureInterval(6, 10, 1)
  WDS.AddFailureInterval(11, 15, 1)

Latest revision as of 17:59, 16 January 2018

APIWiki.png


Member of: SynthesisAPI.WeibullDataSet


Adds interval censored failures to the data set.

Syntax

.AddFailureInterval(StartValue, EndValue, NumberInGroup)

Parameters

StartValue

Required. Double. The starting value of the failure interval.

EndValue

Required. Double. The ending value of the failure interval.

NumberInGroup

Required. Double. The number of failures that occurred during the interval.

Example

VBA

 'Declare a new WeibullDataSet object.  
  Dim WDS As New WeibullDataSet
 
 'Add three interval censored data points.  
  Call WDS.AddFailureInterval(1, 5, 1)
  Call WDS.AddFailureInterval(6, 10, 1)
  Call WDS.AddFailureInterval(11, 15, 1)
VB.NET

 'Declare a new WeibullDataSet object.  
  Dim WDS As New WeibullDataSet
 
 'Add three interval censored data points.  
  WDS.AddFailureInterval(1, 5, 1)
  WDS.AddFailureInterval(6, 10, 1)
  WDS.AddFailureInterval(11, 15, 1)