T-H Example: Difference between revisions

From ReliaWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 1: Line 1:
<noinclude>{{Banner_ALTA_Examples}}
<noinclude>{{Banner_ALTA_Examples}}
''This example appears in the [[Temperature-Humidity_Relationship#T-H_Weibull|Accelerated Life Testing Data Analysis Reference]] book.''
''This example appears in the [https://help.reliasoft.com/reference/accelerated_life_testing_data_analysis Accelerated life testing reference].''


</noinclude>
</noinclude>

Latest revision as of 19:03, 18 September 2023

ALTA Examples Banner.png


New format available! This reference is now available in a new format that offers faster page load, improved display for calculations and images and more targeted search.

As of January 2024, this Reliawiki page will not continue to be updated. Please update all links and bookmarks to the latest references at ALTA examples and ALTA reference examples.




This example appears in the Accelerated life testing reference.


The following data were collected after testing twelve electronic devices at different temperature and humidity conditions:

Ex1chp9.png

Using ALTA, the following results were obtained:

[math]\displaystyle{ \begin{align} \widehat{\beta }=\ & 5.874395 \\ & & \\ \widehat{A}=\ & 0.000060 \\ & & \\ \widehat{b}=\ & 0.280599 \\ & & \\ \widehat{\phi}=\ & 5630.329851 \end{align}\,\! }[/math]

A probability plot for the entered data is shown next.

Probability plots at the tested combinations.

Note that three lines are plotted because there are three combinations of stresses, namely, (398K, 0.4), (378K, 0.8) and (378K, 0.4).

Given the use stress levels, time estimates can be obtained for a specified probability. A Life vs. Stress plot can be obtained if one of the stresses is kept constant. For example, the following picture shows a Life vs. Temperature plot at a constant humidity of 0.4.

Life vs. Temperature plot with humidity fixed at 0.4.