ALTAGeneralOptions Class: Difference between revisions

From ReliaWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(23 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Template:APIClass|GlobalStuff Weibull Class|GlobalStuff Weibull}}
{{Template:API}}{{Template:APIBreadcrumb}}


This class describes various settings for the [[WeibullDataSet Class|WeibullDataSet]].


== Declaration  ==
Represents the calculation settings of the associated [[ALTADataSet Class|ALTADataSet]] object. Applies to the cumulative damage life-stress model only.


{{Template:ALTAGeneralOptions.AllowLargeBetaValues}}
== Properties  ==
{| {{APITable}}
|-
| style="width: 220px;"|AllowLargeBetaValues||Indicates whether the analysis allows beta values up to 250. '''Boolean'''. Default value = False (maximum beta value is 100).
|-
|ImplementStressAtTheEndOfTheStep||Applies to time-dependent stress profiles only. Indicates whether to apply the stress at the end of a segment. '''Boolean'''. Default value = False (the stress is applied at the beginning of the step).
|}


{{Template:ALTAGeneralOptions.ImplementStressAtTheEndOfTheStep}}
 
== Example ==
The following example demonstrates how to initialize the settings for a particular ALTADataSet object.
 
'''VBA|VB.NET'''
{{APIComment|'Declare a new ALTADataSet object.}}
  {{APIPrefix|Dim}} ADS {{APIPrefix|As New}} ALTADataSet
 
{{APIComment|'Specify the settings.}}
  ADS.GeneralSettings.AllowLargeBetaValues = False
  ADS.GeneralSettings.ImplementStressAtTheEndOfTheStep = False

Latest revision as of 20:37, 24 June 2016

APIWiki.png


Member of: SynthesisAPI


Represents the calculation settings of the associated ALTADataSet object. Applies to the cumulative damage life-stress model only.

Properties

Name Description
AllowLargeBetaValues Indicates whether the analysis allows beta values up to 250. Boolean. Default value = False (maximum beta value is 100).
ImplementStressAtTheEndOfTheStep Applies to time-dependent stress profiles only. Indicates whether to apply the stress at the end of a segment. Boolean. Default value = False (the stress is applied at the beginning of the step).


Example

The following example demonstrates how to initialize the settings for a particular ALTADataSet object.

VBA|VB.NET

 'Declare a new ALTADataSet object. 
  Dim ADS As New ALTADataSet
 
 'Specify the settings. 
  ADS.GeneralSettings.AllowLargeBetaValues = False
  ADS.GeneralSettings.ImplementStressAtTheEndOfTheStep = False