ALTADataSet.AddFailureInterval: Difference between revisions
Jump to navigation
Jump to search
Kate Racaza (talk | contribs) No edit summary |
Kate Racaza (talk | contribs) No edit summary |
||
Line 22: | Line 22: | ||
''Stress()'' | ''Stress()'' | ||
:Required. Object. | :Required. Object. Can be an array of numeric stress values or an [[ALTAStressProfile_Class|ALTAStressProfile]] object (stress profiles apply to the cumulative damage (CD) model only). | ||
''Stress1'' | ''Stress1'' | ||
:Required. Object. | :Required. Object. Can be a numeric stress value or an [[ALTAStressProfile_Class|ALTAStressProfile]] object (stress profiles apply to the cumulative damage (CD) model only). | ||
''Stress2'' | ''Stress2'' | ||
:Required. Object. | :Required. Object. Can be a numeric stress value or an [[ALTAStressProfile_Class|ALTAStressProfile]] object (stress profiles apply to the cumulative damage (CD) model only). | ||
Revision as of 21:10, 15 April 2016
Member of: SynthesisAPI.ALTADataSet
Adds interval censored failures to the data set.
Syntax
.AddFailureInterval(StartValue, EndValue, NumberinGroup, ByRef Stress())
.AddFailureInterval(StartValue, EndValue, NumberinGroup, Stress1)
.AddFailureInterval(StartValue, EndValue, NumberinGroup, Stress1, Stress2)
Parameters
StartValue
- Required. Double. The starting value of the failure interval.
EndValue
- Required. Double. The ending value of the failure interval.
NumberinGroup
- Required. Integer. The number of failed units at the time of failure.
Stress()
- Required. Object. Can be an array of numeric stress values or an ALTAStressProfile object (stress profiles apply to the cumulative damage (CD) model only).
Stress1
- Required. Object. Can be a numeric stress value or an ALTAStressProfile object (stress profiles apply to the cumulative damage (CD) model only).
Stress2
- Required. Object. Can be a numeric stress value or an ALTAStressProfile object (stress profiles apply to the cumulative damage (CD) model only).
Example
The following example demonstrates how to add interval censored failures to an ALTADataSet object.
VBA 'Declare a new ALTADataSet object. Dim ADS As New ALTADataSet 'Define 2 stress types with use stress levels = 10 and 25. Call ADS.AddStressDefinition("Stress1",,10) Call ADS.AddStressDefinition("Stress2",,25) 'Add 2 interval censored data points for Stress1 = 190 and Stress2 = 235. 'The failures occurred between time = 10 and time = 20. Dim Stress(1) As Variant Stress(0) = 190 Stress(1) = 235 Call ADS.AddFailureInterval(10, 20, 2, Stress)
VB.NET 'Declare a new ALTADataSet object. Dim ADS As New ALTADataSet 'Define 2 stress types with use stress levels = 10 and 25. ADS.AddStressDefinition("Stress1",,10) ADS.AddStressDefinition("Stress2",,25) 'Add 2 interval censored data points for Stress1 = 190 and Stress2 = 235. 'The failures occurred between time = 10 and time = 20. ADS.AddFailureInterval(10, 20, 2, 190, 235)