The following temperature non-thermal life stress relationship is used | The following temperature non-thermal life stress relationship is used: | ||
::<math>\,\!L\left ( f,T \right )=Af^{B}e^{\left ( \frac{E_{a}}{kT} \right )}</math> | ::<math>\,\!L\left ( f,T \right )=Af^{B}e^{\left ( \frac{E_{a}}{kT} \right )}</math> | ||
where <math>\,\!f</math> is the switching rate, <math>\,\!T</math> is temperature. <math>\,\!L\left ( f,T \right )</math> is the life characteristic affected by the two stresses. This relationship is called temperature non-thermal model in ALTA. | where <math>\,\!f</math> is the switching rate, <math>\,\!T</math> is temperature. <math>\,\!L\left ( f,T \right )</math> is the life characteristic affected by the two stresses. This relationship is called temperature non-thermal model in ALTA. | ||
This relationship also can be expressed as the following: | This relationship also can be expressed as the following: | ||
Line 99: | Line 100: | ||
::<math>\,\!ln\left ( L\left ( x_{1},x_{2} \right ) \right )=\alpha _{0}+\alpha _{1}x_{1}+\alpha _{2}x_{2}</math> | ::<math>\,\!ln\left ( L\left ( x_{1},x_{2} \right ) \right )=\alpha _{0}+\alpha _{1}x_{1}+\alpha _{2}x_{2}</math> | ||
where <math>\,\!x_{1}=\frac{1}{T}</math> and <math>\,\!x_{2}=ln\left ( f \right )</math> . This is the General log-linear model with the proper stress transformation in ALTA. | |||
[[image: .png|center]] | |||
The failure time distribution is a Weibull distribution. The book has the following results: | |||
*The maximum likelihood estimation (MLE) results for the parameters are: <math>\,\!\alpha _{0}=0.671</math> , <math>\,\!\alpha _{1}=4640.1</math> , <math>\,\!\alpha _{2}=-0.445</math> and <math>\,\!\beta =1.805</math>. | |||
*The eta parameter in the Weibull distribution at temperature of 30 °C (303.15 °K) and switching rate of 5 cycles/minute is estimated as . | |||
*The estimated reliability at 200,000 cycles and temperature of 30 °C (303.15 °K) and switching rate of 5 cycles/minute is 0.996. Its one-sided lower 90% confidence bound is 0.992. | |||
*The two-sided 90% confidence interval for parameter is [-0.751, -0.160]. | |||