Template:Nominal time to real goal: Difference between revisions

From ReliaWiki
Jump to navigation Jump to search
(Created page with '====Nominal Time to Reach Goal==== <br> Assuming that we have a target MTBF or failure intensity goal, we can solve Eqn. (Nominal FI) to find out how much test time, , is requi…')
 
 
Line 1: Line 1:
====Nominal Time to Reach Goal====
#REDIRECT [[Reliability_Growth_Planning#Nominal_Time_to_Reach_Goal]]
<br>
Assuming that we have a target MTBF or failure intensity goal, we can solve Eqn. (Nominal FI) to find out how much test time,  , is required, (based on the Crow Extended model and the nominal idealized growth curve) to reach that goal:
 
 
::<math>{{t}_{N,G}}={{\left[ \frac{{{r}_{G}}-{{\lambda }_{A}}-(1-d){{\lambda }_{B}}}{d\cdot \lambda \cdot \beta } \right]}^{\tfrac{1}{\beta -1}}}</math>
 
 
Note that when  <math>{{\lambda }_{I}}<{{r}_{G}}</math>  or, in other words, the initial failure intensity is lower than the goal failure intensity, there is no need to solve for the nominal time to reach the goal, because the goal is already met. In this case, no further reliability growth testing is needed.

Latest revision as of 01:47, 27 August 2012