==Test Design Using a Life Difference Detection Matrix==
#REDIRECT [[Reliability Test Design]]
 
Engineers often need to design tests for detecting life differences between two or more product designs. The questions are how many samples and how long should the test be conducted in order to detect a certain amount of difference. There are no simple answers. Usually, advanced design of experiments (DOE) techniques should be utilized. For a simple case, such as comparing two designs, the Difference Detection Matrix in Weibull++ can be used. The difference detection matrix graphically indicates the amount of test time required to detect a statistical difference in the lives of two populations.
 
As discussed in the test design using expected failure times plot, if the sample size is known, the expected failure time of each test unit can be obtained based on the assumed failure distribution. Now let's go one step further. With these failure times, we can then estimate the failure distribution and calculate any reliability metrics. This process is similar to the simulation used in [[Weibull SimuMatic|Simumatic]] where random failure times are generated from simulation and then used to estimate the failure distribution. This approach is also used by the difference detection matrix.
 
Assume we want to compare the B10 lifes (or mean lifes) of two designs. The test is time-terminated and the termination time is set to ''T''. Using the method given in [[Reliability Test Design#Test Design Using Expected Failure Time Plots|Test Design Using Expected Failure Time Plots]], we can generate the failure times. For any failure time greater than ''T'', it is a suspension and the suspension time is ''T''. For each design, its B10 life and confidence bounds can be estimated from the generated failure/suspension times. If the two estimated confidence intervals overlap with each other, it means the difference of the two B10 lifes cannot be detected from this test. We have to either increase the sample size or the test duration.
 
 
'''Example 7:'''
{{Example: Test Design Using Life Difference Detection Matrix}}