T-H Example

From ReliaWiki
Revision as of 21:53, 21 March 2012 by Nikki Helms (talk | contribs) (Created page with '{| class="FCK__ShowTableBorders" border="0" cellspacing="0" cellpadding="0" align="center"; style="width:100%;" |- | valign="middle" align="left" bgcolor=EEEDF7|[[Image: ALTA-Exa…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
ALTA-Examples-banner.png


The following data were collected after testing twelve electronic devices at different temperature and humidity conditions:

Ex1chp9.png



Using ALTA, the following results were obtained:


[math]\displaystyle{ \begin{align} \widehat{\beta }=\ & 5.874395 \\ & & \\ \widehat{A}=\ & 0.000060 \\ & & \\ \widehat{b}=\ & 0.280599 \\ & & \\ \widehat{\phi}=\ & 5630.329851 \end{align} }[/math]


A probability plot for the entered data is shown next.


Probability plots at the tested combinations.



Note that three lines are plotted because there are three combinations of stresses, namely, (398K, 0.4), (378K, 0.8) and (378K, 0.4).


Given the use stress levels, time estimates can be obtained for specified probability. A Life vs. Stress plot can be obtained if one of the stresses is kept constant. For example, the following picture is a Life vs. Temperature plot at a constant humidity of 0.4.

Life vs. Temperature plot with humidity fixed at 0.4.